Must See: The New LightSPEED Zulu Headset
 

Call us toll-free 1-877-314-7575
Gift Certificates Available
 

 Cart | Your Account | Help

Search:
  You have 0 items in your cart. Check Out Now.
 

 More products from SkyOx

     
SkyOx 6 Cubic Foot Oxygen 2 Place System information
List Price: $470.00
Our Price:  $445.00

Product # 5282

Add SkyOx 6 Cubic Foot Oxygen 2 Place System To Cart

Email to a Friend


 Questions?

 
Write a Review

 

 

 

 

 

SkyOx 6 Cubic Foot Oxygen 2 Place System

SkyOx 6 Cubic Foot Oxygen 2 Place System

FAA Requires Use Of Supplemental Oxygen - When flying above 12,500 ft. for more than 30 minutes, or flying above 14,000 ft., pilots and crew members are required to use oxygen. Above 15,000 ft., all occupants, including passengers, must be provided with supplemental oxygen. 

Sky Ox - A Complete System 

  • Self Contained Unit 
  • No Installation required 
  • Easy to Use 
  • No FAA weight and balance change necessary 
  • Includes Pressurized Cylinder with Oxymizer Cannulas, lines, flow indicator, quick disconnects, and spare mask. 
  • Easy to Refill (Simple & Inexpensive) Refill with aviation-grade breathing Oxygen (MIL-027210, Type1) 
  • Lightweight aluminum cylinder is easy to fasten to the back of a cockpit seat. Truly Portable. 
  • Adjustable Flow Regulator set by altitude or special flow. As you change altitude, adjust the flow control valve for more or less oxygen (the upper gauge shows altitude and flow setting, the lower gauge shows remaining cylinder pressure). 

Easy To Use 

  • When reaching proper altitude, turn the control valve on the Adjustable Flow Regulator to the proper flow; Oxygen flows when a breathing apparatus is plugged into any one of the ports. Unused ports remain sealed. 
  • Flow does not have to be adjusted if using more than one outlet. 
  • Check charts provided with cannulas for proper flow setting. 

Oxymizer Cannula 

  • Reduces oxygen usage over 50% 
  • Stores oxygen in the pendant reservoir. 
  • Pendant rests on your chest and not your lip. 
  • Free to drink a beverage & talk in total comfort. 
  • Use Cannula up to 18,000 ft. 
  • Use with the Adjustable Regulators or A-3 Flowmeter 
Model SK12-6 SK12-9 SK12-15 SK12-24
Size  (D x L) 3-1/4" x 16-3/8" 4-3/8" x 15-1/2" 4-3/8" x 21-1/4" 4-3/8" x 30-1/4"
Weight 6 lbs. 7 lbs. 11 lbs. 14 lbs.
Cubic Feet 6 CU. FT. 9 CU. FT. 15 CU. FT. 24 CU. FT.
Capacity 198 liters 297 liters 495 liters 792 liters
Construction Aluminum Aluminum Aluminum Aluminum
Included 2 oxymizer cannulas
1 mask
2 oxymizer cannulas
1 mask
2 oxymizer cannulas
1 mask
2 oxymizer cannulas
1 mask
Duration* 5:28 hours 8:07 hours 13:48 hours 22:42 hours
Order Order a 2 Place System

Order a 4 Place System

Order a 2 Place System

Order a 4 Place System

Order a 2 Place System

Order a 4 Place System

Order a 2 Place System

Order a 4 Place System

*  Duration is man-hours at 15,000 ft. with Oxymizer

Please note, all oxygen systems are shipped empty by default because it is considered to be hazardous materials by the shipping companies.  If you need it to be shipped full, please make a note of it in the comments section during checkout.  A $30.00 hazardous materials surcharge will be added to filled oxygen systems.  Full tanks cannot be shipped via Next Day or Second Day Air service.

 

List Price: $470.00
Our Price:  $445.00

Add SkyOx 6 Cubic Foot Oxygen 2 Place System To Cart

Related Shopping Areas:
Oxygen SystemsSkyOx Oxygen Systems
Aircraft SuppliesOxygen

Lowest Price Guaranteed: If you find a better price elsewhere on this product we will match that price and beat it by 10% of the difference.

Buy With Confidence!  Purchase today and you can return it in the original condition through Monday, October 06, 2008!  Our return policy.

Have a question about SkyOx 6 Cubic Foot Oxygen 2 Place System?  Ask your question and see previous Q & A about this product.

 

Customer Reviews For SkyOx 6 Cubic Foot Oxygen 2 Place System:
Write a review
No reviews have been posted for this product yet.


 

 
Tags Associated With This Product (what's this?):  None yet, add a tag!
Suggest a new tag:

 

Previous Customer Questions For SkyOx 6 Cubic Foot Oxygen 2 Place System:
Ask Your Own Question
On Thursday, January 10, 2008 a customer asked:
Q:
What would be the Duration for SK12-6 at 10000 ft (~3km) using a) oxymizer or b) mask.

We were thinking of using SK12-6 for (4) pax, but need 1hr of O2 per pax @ 3km , with mask preferable to oxymizer.
A: At 15,000 feet, the mask will give you about 1 hour 49 minutes of total oxygen (less than 30 minutes for each of the 4 passengers). With the cannulas you should get about 5 hours 28 minutes of oxygen (more than enough).

If you want to use the mask and need four hours of oxygen you will need to step up to the SK12-15 which will give you about 4:36 hours with the mask (13:48 with the cannulas) at 15,000 feet.


 

home  |  feedback  |  view cart  | tagsprivacy and security policy

Need Help?  Email us at service@MyPilotStore.com
Phone 480-556-0500 or 877-314-7575

More websites:  Aircraft for Sale -- Airport/Facility Directory -- FAA Written Exams

Copyright © 1998-2008 by MyPlane, Inc. All Rights Reserved.
Please Read Our Terms of Use..

Saturday, September 06, 2008

Some keywords that may help you find this product: SkyOx 6 Cubic Foot Oxygen 2 Place System SkyOX SK 12-6 2 Place Provides about 5.5 man-hours of oxygen. Includes 2 cannulas and 1 mask. Lightweight, portable oxygen system.